2020 Phillips and Temro Catalog
KUBOTA – CONTINUED
V2607, V3307, V3600, V3800 Part No. Watt Volt
Diameter 1" NPT
Type
Repl. Cord
3500120 400
120
Immersion 3600110
Installation Information: Replaces 1" NPT pipe plug. V3300 Part No. Watt Volt Diameter
Type
Repl. Cord
3100093 400 Immersion 3600003 Installation Information: Install in Right Front (RF). Use 1" x 3/4" pipe bushing. 120 3/4" NPT
V4000B, V4300B (3 cyl.) Part No. Watt 3100003 400
Volt 120
Diameter 1" NPT
Type
Repl. Cord
Immersion 3600001
Installation Information: Install in front.
Z400, Z482, D722* (Super Mini/New Super Mini 2 cyl.) Part No. Watt Volt
Diameter
Type
Repl. Cord
3100099 400
120
30mm Freeze Plug 3600004
Installation Information: Install in back of head. * Kubota D722: use 3100099 on Tier 2 or older; use 3100132 on newer D722 (needs a pound in heater due to change in valve cover).
Z600 & ZH600 (Super Mini/New Super Mini 2 cyl.) Part No. Watt Volt
Diameter
Type
Repl. Cord
3100093 400 Immersion 3600003 Installation Information: Install Right Front (RF). Use 1" x 3/4" pipe bushing. Z602-D902-WG, DF, DG972, D722 (Newer than Tier 2) (Super Mini 02 Series 73.6mm Stroke) Part No. Watt Volt Diameter Type Repl. Cord 3100132 400 120 30mm Freeze Plug 3600083 Installation Information: Rear of cylinder head in rear frost plug hole, knock in type, tapered body 120 3/4" NPT LPW Series (1994 & newer 56 CID 2 cyl., 85 CID 3 cyl., 113 CID 4 cyl.) Part No. Watt Volt Diameter Type Freeze Plug 3600004 Installation Information: Install between cylinders. Point element UP or DOWN. LOMBARDINI CHD Series: LDW1503, LDW1603 (3 cyl.) , LDW2004, LDW2204, LDW2004T (4 cyl.) Part No. Watt Volt Diameter Type Repl. Cord 3100096 400 120 30mm Freeze Plug 3600004 Installation Information: Install in Left Side (LS). Point element 3 or 9 o’clock. Repl. Cord 3100077 400 120 1-1/4" LISTER-PETTER
phillipsandtemro.com
77
Made with FlippingBook Annual report