HEAVY DUTY SILICONE CONNECTORS TECHNICAL INFORMATION

Silicone Connector

Pin Distance

Pin Diameter

K

0.360”

0.138”

L

0.375”

0.138”

Type B Right Angle

Type K Right Angle

Type L Right Angle

Type M Straight

M

0.360”

0.138”

PLUG TYPES

A 120 Volt 15 Amp

B 240 Volt 15 Amp

C 120 Volt 20 Amp

D 240 Volt 20 Amp

E 120 Volt – 15 Amp No Ground

F 125 Volt – 30 Amp

G 250 Volt – 30 Amp

PLUG TYPE

STANDARD MALE PLUGS

NEMA 1-15 NEMA L5-30 NEMA L6-30

NEMA 5-15 NEMA 6-15 NEMA 5-20 NEMA 6-20

WEATHERPROOF MALE PLUGS

NA

NA

NA

NA

A (WP)

B (WP)

C (WP)

EXTENSION CORDS Cord Selection and Usage:

When using an extension cord with one or more heating devices, it is important that the TOTAL current draw of all devices not exceed the capacity of the extension cord or the AC circuit. Use only 3-wire GROUNDED extension cords. Ground Fault Interrupter (GFI) service is also recommended. Recommended Wire Gauges – Long Length power supply Cords Current Carrying Capacity - Amps Length 4 6 8 10 12 14 16 18 20

25 12 10 10 10

16 14 14 14 12

16 14 14 14 12

14 12 12 12 10

14 12 12 12 10

12 12 12 10 10

15 25 50

18 18 18 16 16

18 18 18 16 14

16 16 16 14 12

16 16 16 14 12

100 150