2020 Phillips and Temro Catalog

COOLANT CIRCULATION PUMP COOLANT WARMING ACCESSORIES

®

Used to "boost" coolant flow in Arctic Fox® Fuel & Fluid Temperature Management Systems, when multiple heat exchangers are installed or for remote tank installations that require long lengths of plumbing

Recommended Temp Range to +20�F / -7�C to +20�F / -7�C to +20�F / -7�C to -40�F / -40�C to -40�F / -40�C

Pressure PSI/Bar

Part Number A-1600-12V A-1600-24V A-1600-115V * A-4350-12V A-4350-24V

Description 12V DC Pump 24V DC Pump 115V AC Pump 12V DC Pump 24V DC Pump

Amp Draw

GPM/LPM

8.5 4.3 1.0

8/30 8/30 8/30

4/.28 4/.28 4/.28 8/.55 8/.55

10.1

10/38 10/38

5.1

* Dimensions shown do not pertain to the A-1600-115V

DIMENSIONS

8.0" (203mm)

3/4" NPT Coolant Out

4.0" (102mm)

3/4" NPT Coolant In

4.0" (102mm)

2.0" (50mm)

RELAY & BRACKET – DS 12V & 24V

Allows 12 and 24 volt DC pumps to be operated with minimal current draw through a switch or other triggering mechanism.

Part Number

Description

KT-1904 KT-1941

Relay & Connector Bracket for 12V DC System Relay & Connector Bracket for 24V DC System

Terminal

Connection

Battery + for negative ground systems Battery – for negative ground systems

30

87 (NO) 30 Amp

85 86

87A (NC) 30 Amp

Switch or triggering mechanism

86

85

Ground

Brown pump wire on negative ground or insulated systems. Black pump wire for positive ground systems Normally closed contact—not used

30

87 (NO)

87a (NC)

Relay Terminal Connection B-715 02/13

phillipsandtemro.com

156

Made with FlippingBook Annual report