2023 Phillips and Temro Product & Application Guide

HOTLINE ® ELECTRIC IN-LINE FUEL & FLUID WARMERS

®

INSTALLATION DIAGRAM

Toggle Switch Item 2

Control Power From Fuse Panel (Keyed—ON/Off/Accessory) Item 1

D3061-1677 Ground for Light

Orange Control Power

White Ground in cab

Red for light

Fuse

D3061-1735 3-Wire Harness

Red

Optional Temp Limit Switch Part# D3065-2338 12 & 24 Volt Off @ 80°F (27°C) On @ 55°F (13°C)

Shell Connector Inside Cab

D3061-1735 3-Wire Harness

Orange

To Fuel Pump

White

Blue-If Limit Switch is Installed Orange-If Limit Switch is NOT installed

Fuel Filter

White

Red For Light

D3061-1664

D3065-2360

D3061-1573 (12V) D3061-1575 (24V) Magnetic Switch

D3061-1560 (12V) D3061-1565 (24V) Circuit Breaker

HOTLINE ®

D3065-2284 Insulating Boot

D3061-1638 From Alternator Output Terminal

D3065-2357

SERVICE PARTS

Part Number Description D3061-1677 Black Jumper 14 Gauge

Part Number D3061-1573 D3061-1575 D3061-1560 D3061-1565

Description

12V Magnetic Switch 24V Magnetic Switch

D3061-1582 D3061-1584

12V Lighted Toggle Switch 24V Lighted Toggle Switch

12V 60 Amp Circuit Breaker 24V 60 Amp Circuit Breaker

D3065-2338 Optional Thermostat 55-80°F (13-27°C) Kit D3061-1735 3-Wire Harness Kit D3065-2360 Wire Jumper Magnetic Switch D3061-1664 #10 Jumper Main Power

D3061-1638 #4 Jumper Main Power–47" D3065-2357 Ground Rubber Wire 96" (2.4m) D3065-2284 Insulating Boot

phillipsandtemro.com

128