2023 Phillips and Temro Product & Application Guide

®

CIRCULATION HEATER WATTAGE FOR STATIONARY APPLICATIONS

Size of Engine (L)

Recommended Wattage**

Heat Rise* °F

Heat Rise* °C

Warm Up Time

2 Hours 4 Hours 8 Hours 2 Hours 4 Hours 8 Hours 2 Hours 4 Hours 8 Hours 2 Hours 4 Hours 8 Hours 2 Hours 4 Hours 8 Hours 2 Hours 4 Hours 8 Hours 2 Hours 4 Hours 8 Hours 2 Hours 4 Hours 8 Hours 2 Hours 4 Hours 8 Hours 2 Hours 4 Hours 8 Hours 2 Hours 4 Hours 8 Hours 2 Hours 4 Hours 8 Hours 2 Hours 4 Hours 8 Hours 2 Hours 4 Hours 8 Hours 2 Hours 4 Hours 8 Hours 4 Hours 8 Hours 4 Hours 8 Hours 4 Hours 8 Hours 4 Hours 8 Hours 8 Hours 8 Hours 8 Hours 8 Hours 8 Hours

1500 750 375 900 500 943 471 1800 1900 2330 1165 2775 1390 3432 1716 4197 2098 1049 5184 2592 1296 4862 2416 1213 6000 3000 1499 5673 2836 1418 7009 3504 1752 9610 4804 2402 582 694 857 2612 6455 3227 7543 3771 9318 4659 6981 6511 8043 7292 9007 11871 5935 10452 5226 2967 11303 5654

85°F

47°C

4 Liter

105°F

58°C

85°F

47°C

6 Liter

105°F

58°C

85°F

47°C

9 Liter

105°F

58°C

85°F

47°C

13 Liter

105°F

58°C

85°F

47°C

15 Liter

105°F

58°C

85°F

47°C

18 Liter

105°F

58°C

85°F

47°C

27 Liter

105°F

58°C

85°F

47°C

32 Liter

*Heat rise calculations are based on wattage required to achieve the listed heat rise. **If the engine is exposed to a wind load select the highest wattage available for that engine size. Additional questions, contact a sales manager to help you determine what circulation heater is right for your application – sales@phillipsandtemro.com.

105°F

58°C

85°F

47°C

35 Liter

105°F

58°C

85°F

58°C 47°C 58°C 47°C 58°C 47°C

50 Liter

105°F 85°F 105°F

60 Liter

85°F

69 Liter

105°F

phillipsandtemro.com

109

Made with FlippingBook Ebook Creator