2017 Zerostart Temro Catalog
DIESEL STARTING FLUID SYSTEMS Starting Fluid System Atomizers • Designed for most engines with 1/8" or 1/4" NPT opening • Provides proper direction and atomization of pressurized fluid
Atomizer (see below) (1/8" x 1-1/4")
Dual Atomizer Kit (for use with “V’ engines) #8203091
1/4" Bushing #8203032
• Sintered bronze filter maintains purity of intake air • Spray pattern clearly marked for easy installation
Atomizer Applications Part No. Orifice/Size Applications
Location
Spray Pattern
8203067 Caterpillar 3406B Turbo Pre-tapped hole in aftercooler .018 8202931 Cummins B & C Series Pre-tapped manifold .011 8202966* Cummins Non-Turbo Center intake manifold .018 & other manifolds over 2" Blue Detroit Diesel blower box Center blower box 8202990 Mack in-line 6 Pre-tapped hole between .018 cylinders #5 & #6 8203016 Mack Midliner Air intake pipe or intake manifold .013 Under 500 CID Ford 6.6/7.8L, Cummins 8202974* & Perkins in-line, all .013 Turbocharged engines Yellow 8200003 Cummins 600 Direct either flow against .018 Swivel Style flow of incoming air 8200004 Cummins 600 .013 Swivel Style Over
450 CID (Pressure side of turbo), 8202982* DDA or IH Air Intake Horn
.018 Red 8202958 DDA 8.2 Litre
Pre-tapped hole in air cleaner adapter
.013 8203008 Ford industrial diesel
Direct flow of starting fluid into air stream,
Heating & Accessory Products
.018
not directly into cylinder.
*Included in kit 8203237 Note: All atomizers 1/8" NPT.
• Locks out electrical valve operation at specified engine temperatures • Surface mount installs without draining engine coolant • Threaded 1/2" NPT installs directly in any 1/2" NPT opening in water jacket Diesel Starting Fluid System Thermostats
Threaded Style
Surface Mount
Part No.
Type
Temp ON
Temp OFF 85°F (29°C) 65°F (18°C) 100°F (38°C)
8200386 Surface Mount
60°F (16°C) 45°F (7°C) 70°F (21°C)
8202281 Threaded 8291837 Threaded
1-800-328-6108 or 952-941-9700 • phillipsandtemro.com